A Complete Guide to the Power Flame Type C Burner

A Complete Guide to the Power Flame Type C Burner

The Power Flame Type C burner boasts an ultramodern design for unparalleled operating dependability and combustion efficiency. These combustion systems are engineered to fire gas, light oils, gas/light oil, and a wide range of liquid fuels within the #2 fuel oil viscosity range.

With an expansive firing spectrum ranging from 300,000 - 19,100,000 BTU/HR, the Power Flame Type C Burner is available in the following models:

  • CG (Gas Burner)
  • CO (Light Oil Burner)
  • CGO (Gas-Light Oil Burner)
  • CG HTD (Gas Burner High Turndown)
  • Forced Draft Burners

Technological Features of the Power Flame Type C Burner

The modular design of the Power Flame Type C Burner produces increased flexibility and allows a long list of standard and optional features.

Unique Blast Tube and Firing Head Construction

The Power Flame Type C Burner is highlighted by the advanced construction of the firing head and blast tube. This construction allows the burner to be most effectively applied to several retrofit applications - by firing through the existing fire door. In contrast, competing burners would have to cut through the water wall to accommodate the larger diameter and shorter blast tube and firing head.

Adjustable Pre-mix Firing Head

The optional adjustable pre-mix firing head produces optimum fuel-air mixture within the pre-mix combustion zone. This feature shortens the flame and maximizes stability, which adds a significant amount of flexibility to tough-firing applications. It also allows you to achieve lower gas supply pressures than the competition.

Convenient Side Orifice Tee Design

Power Flame features a "side orifice tee" design, which allows for the modification of firing rates and gas pressure at an easy-to-access location - in the gas train outside of the burner. In contrast, competing burners use "multi spud orifices" and are mounted inside of the firing head. This complicates servicing the burner or making adjustments. It also requires the technician to climb into the combustion chamber or remove the burner from the heat exchanger.

Easy Total Access Panel

The Total Access Panel allows the operators to gain unencumbered access to all of the essential components mounted inside of the burner control panel. The swing-out, easily removable front and top panels offer total access to the internal panel-mounted components.

Characterized Fuel Metering

The Optional Varicam® characterized 14-point, cam-actuated, fuel metering device provides accurately repeatable and fully adjustable fuel-air ratios throughout the firing range. It is applicable for gas, oil, and combination oil/gas modulating burners.

Graphic Burner Management System

With the optional Director™ Graphic Burner Management System, you will have access to a high-quality graphic display of the most critical burner functions. This cutting-edge feature simplifies the management of your burner system.

Power Flame Type C Standard Equipment

Regardless of the Power Flame Type C Burner model, all combustion systems are factory fire-tested to ensure the most cost-effective start up and installation.

Power Flame Type C Model CG

These systems are designed to fire natural gas and a wide spectrum of waste or other gaseous fuels. The Model CG HTD fires natural gas at turndowns up to 10 to 1. The standard equipment on the Power Flame Type C Model CG includes:

  • Alpha System LED (demand, power, FSG alarm, main fuel) and control switch
  • Alpha System LED (demand, power, FSG alarm, main fuel) and control switch
  • Leakage test cock, main gas cock, pilot cock
  • Gas ignition transformer and gas electric pilot
  • Air safety switch
  • Pilot and main gas pressure regulators

Power Flame Type C Model CO

These packaged combustion systems will fire a vast range of liquid fuels within the #2 fuel oil viscosity range. The standard equipment on the Power Flame Type C Model CO includes:

  • Alpha System LED indicator (power, demand, main fuel, FSG alarm, selectable) and control switch
  • 3450 RPM Motor, oil valves, squirrel cage blower, direct spark ignition, nozzle assembly

Power Flame Type C Model CGO

The Power Flame Type C Model CGO package combustion systems will fire all kinds of gaseous fuels, including #2 or related distillate liquid fuels. The Model CGO HTD will fire natural gas at turndowns up to 10 to 1. The standard equipment on this model includes.

  • Pressure regulators, main and pilot gas cocks
  • Alpha System LED indicator (power, demand, main fuel, FSG alarm, selectable) and control switch
  • Nozzle assembly, oil valve, manual fuel selector switch
  • Leakage cock test and air safety switch
  • Gas ignition transformer and gas electric pilot

Contact ATI of New York for the Power Flame Type C Burner

The modular design of Power Flame burners allows the manufacturer to provide a vast range of burners, panel boxes, and component configurations at a highly competitive price. As the authorized Power Flame representative, ATI of New York offers the full lineup of Power Flame Type C Burners.

Contact an ATI of New York sales engineer today to learn more about the versatility of the Power Flame Type C Burner.